Skip to main content Scroll Top

XTN

XTN – CDR Pompe

Technical documents

XTN-BL – magnetically driven with an open impeller

The Series X it is suitable for applications with corrosive, toxic, or hazardous liquids when:

• The liquids being pumped have a high concentration of solids, therefore the use of a standard magnetic drive pump would cause frequent blockages and failures;
• a pump that complies with normative ATEX (ATEX Zone 1 indoor and outdoor).

The circulation of the fluid laden with solid particles is ensured by the large flushing channels within the pump. This way, the diamond bushings and the cup are properly cooled. The axial flushing hole in the impeller shaft also ensures a continuous exchange of pumped liquid between the cup and the volute.

Maximum allowable temperature up to +160°.

Main technical features of the model:

Sealing System Magnetic Drag
Design: EN 22858; ISO 2858; ISO 15783
Body Material: PFA Lined
Bushings/Shaft Material: Diamond Compound
Body Type: Radially Split Volute Casing
Spinning Material PFA Lined
Rotor Type: Open
Aspiration Position End suction
Pull-out design Yes
Heating Shirt North America
Connection Types: Flanged
Flange UNI 1092-2 (ISO 7005-2) PN16RF
slotted to ANSI 150
Self-priming Non-priming
Lubricant North America
Maximum Pressure Range @20°C: Pressure Nominal 16
Fluid Temperature Range: PFA: -50°C / +160°C
Maximum prevalence @ 2900 RPM: 60 meters
Maximum Flow @ 2900 RPM: 70 m³/h
Viscosity Range 0.5 cSt – 180 cSt
Maximum Installable Power 18.5 kW

APPLICATIONS

Discover all of our application areas
For pumps:

Sign up for our newsletter

Get an exclusive look at the latest products and the most important news.