Skip to main content Scroll Top

Application Sector

Pharmaceutical

The chemical-pharmaceutical industry uses pure solvents, aggressive reagents and intermediates of very high added value for the synthesis of drugs and treatments that require the highest degree of purity, containment and process repeatability. Even minimal contamination or leakage would compromise the quality compliance of the entire production batch, causing serious financial losses and line downtime. CDR Pompe hermetic centrifugal pumps ensure total isolation of the fluid from the external environment, eliminating fugitive emissions, oxidation and cross-contamination.

Designed in accordance with ISO 2858 and ISO 5199, CDR solutions operate safely in ATEX-classified areas and in cleanrooms or primary synthesis departments, preserving the chemical integrity of the product and protecting operators.

MAIN APPLICATION AREAS:

  • Active pharmaceutical ingredients (APIs) and intermediates: feeding reactors, crystallizers, centrifuges and distillation columns with no release of particles or contaminants.
  • High-purity and flammable solvents: safe transfer of methanol, ethanol, acetone, toluene, dichloromethane, THF and acid-solvent mixtures in ATEX zones.
  • Fine chemicals, plant protection products and agrochemicals: hermetic handling of active formulations, catalysts and highly selective corrosive solutions.
CDR Pompe – Industrial and Process Pumps

Certifications:

Standard ISO 2858 & ISO 5199
ATEX standard
FDA Certification

Pharmaceutical – CDR Pumps

Centrifugal pumps

Discover the industrial pump models used in the following sectors: Chemical, Industrial and Pharmaceutical.
We work in close collaboration with distributors to accurately understand customer needs and propose the most suitable product for their service.

ATEX specifications, FDA certification and cGMP requirements for pharmaceutical plants

In primary synthesis (API) and solvent recovery departments, potentially explosive atmospheres, wide thermal cycles and rigorous validation protocols coexist. CDR Pompe process pumps meet pharmaceutical engineering specifications through dedicated configurations:

  • Hermetic containment with magnetic drive: the absence of dynamic mechanical seals eliminates dripping, toxic vapors and VOC emissions at the source, reducing environmental monitoring and maintenance work in the department.
  • FDA-compliant virgin PFA and antistatic PFA linings: for ultrapure and corrosive fluids we use thick linings in virgin white PFA (FDA 21 CFR 177.1550 compliant, free of releasable pigments), while for pumping non-conductive organic solvents in ATEX Zone 1 and Zone 2 (II 2G) we use conductive PFA, which prevents the buildup of electrostatic charges.
  • AISI 316L stainless steel versions and support for cGMP practices: wetted surfaces with controlled finish, EN / ASME flanged connections, pump casing drain ports and compatibility with in-line cleaning and sterilization cycles (CIP/SIP), supplied with EN 10204 3.1 material certificates, witnessed hydraulic tests and a complete technical file.

Customization examples for pure solvents and API synthesis

Every pharmaceutical plant has specific constraints in terms of layout, NPSH available at the foot of the reactors and temperature range. Among the configurations most widely adopted in European chemical-pharmaceutical departments are:

  • Discharge of reactors and columns with acid-solvent mixtures: PFA-lined UTN and DTN ISO series with dynamic shaft and Pt100 temperature sensors on the containment shell for dry running protection.
  • Cryogenic or high-temperature thermal circuits (-140 °C / +300 °C): UTS EVO metal series in AISI 316L stainless steel for reactor temperature control fluids, anhydrous solvents and heavy-duty continuous service.
  • Retrofits on existing baseplates and special nozzles: development of custom industrial pumps in PFA and steel with full drainage, heating/cooling jackets and integrated instrumentation to the specification of the customer's engineering department.

Frequently asked questions about pumps for the pharmaceutical sector

Which pumps are best suited to the production of active pharmaceutical ingredients (APIs)?

For the synthesis of active ingredients (APIs) and chemical-pharmaceutical intermediates, magnetic drive centrifugal pumps lined in FDA-compliant virgin white PFA (such as the CDR UTN and DTN ISO series) or in AISI 316L stainless steel (UTS EVO series) are preferred, because they ensure a hermetic, zero-leakage seal, chemical purity and no contamination from flushing liquids.

How can electrostatic risk be avoided with pure solvents in a pharmaceutical ATEX zone?

When handling non-conductive solvents (such as toluene, hexane or ethyl acetate) in ATEX Zone 1 or Zone 2 classified areas, CDR Pompe uses conductive antistatic PFA linings and internal components combined with certified grounding and thermal monitoring on the magnetic coupling, preventing internal electrostatic discharges.

Do CDR pumps for the pharmaceutical industry come with FDA certifications and 3.1 traceability?

Yes. On request in the specification, CDR Pompe provides FDA 21 CFR declarations of conformity for the virgin polymers in contact with the product, material analysis certificates according to EN 10204 3.1, ATEX certification and performance and leak tests in the test bay before shipment.

Are you defining the specification for a new API line or for the replacement of a pump on pure solvents? Contact the CDR Pompe Technical Office for a selection tailored to your duty point.

Sign up for our newsletter

Get an exclusive look at the latest products and the most important news.

"*" indicates required fields