Skip to main content Scroll Top

Pressure Losses in Chemical Plants: How They Affect Pump Selection

pressure losses
TLDR
  • Choosing a centrifugal pump for a chemical plant means taking into account the conditions the fluid meets along the entire circuit.
  • Among these, pressure losses play a decisive role because they indicate the energy dissipated as the fluid passes through pipes, bends, valves, fittings, filters, heat exchangers and other components.
  • Their magnitude helps define the head required from the pump and, consequently, its actual duty point.
  • The article analyzes the differences between distributed and localized losses, looking at the influence of pipe length and diameter, fluid velocity, internal roughness and circuit configuration.
  • A dedicated section covers viscosity, a particularly relevant parameter in chemical plants because it can change both the resistance in the lines and the pump performance compared with the curves based on water.
  • It also examines the relationship between pressure losses, available NPSH and cavitation, with attention to the possible consequences for the impeller, performance and service life of the machine.
  • The overall picture shows why flow rate, head, liquid characteristics and plant conditions must be assessed together to select a pump suited to the intended duty.
Index

In a chemical plant, a fluid leaving the suction point must pass through pipes, bends, valves, fittings, filters, heat exchangers and various measuring instruments before reaching its destination. Each of these elements opposes physical resistance to the movement and thus creates what are known as “pressure losses” that the pump must then be able to overcome. Knowing the desired flow rate and the properties of the liquid is the starting point, but selecting a centrifugal pump must also take into account what happens throughout the entire transfer.

Excessive pressure losses can make it difficult for the pump to reach the expected flow rate, or force it to operate in an unfavorable area of its characteristic curve. In chemical plants the calculation takes on added importance because viscosity, pipe characteristics, circuit configuration and suction conditions can significantly change the type of pumps required.

CDR Pompe has worked in the process industry for years and supports its customers not only in selecting centrifugal pumps for aggressive fluids and chemical plants, but also by providing technical expertise, start-up assistance e and preventive maintenance services.

What pressure losses are and why they must be considered

The pressure losses describe the decrease in mechanical energy that a substance undergoes as it passes through the plant circuit: friction with the walls and passage through components that obstruct or alter the flow dissipate part of the available energy. From the pump's point of view, this resistance must be included in the calculation of the head needed to transfer the liquid from the suction point to the discharge point: the greater the overall resistance of the circuit, the greater the head required at a given flow rate.

It is important to distinguish this value from the simple geometric elevation difference in the system: two points at different heights introduce a static component of the head, while the movement of the liquid along the circuit generates additional resistance. Even a system with a small elevation difference can therefore have a significant head requirement if the route is long, has small diameters or includes numerous components.

Distributed losses: what happens along the pipes

The resistance encountered as the fluid flows through a pipe depends on several variables, such as the system layout or the conditions in which the fluid is handled. These aspects can change the overall head losses and, as a result, the head required from the pump.

The main parameters to evaluate include:

  • Pipe length: the longer the fluid path, the larger the surface it contacts and the more energy is dissipated by friction. Particularly long lines can therefore contribute significantly to the overall resistance;
  • Internal pipe diameter: at the same flow rate, a smaller diameter increases the average velocity of the liquid and can cause a significant increase in losses;
  • Fluid velocity: distributed losses are closely tied to velocity. As velocity increases, resistance can grow considerably, especially in turbulent flow;
  • Internal roughness: the material, finish and internal condition of the pipes affect friction. Deposits, scaling or deterioration of the surfaces can also change the hydraulic characteristics of the line over time;
  • Liquid viscosity: the physical properties of the substance influence the flow regime and hydraulic behavior. This parameter is essential when handling chemicals with a viscosity significantly higher than that of water.

Localized pressure losses: bends, valves and circuit components

Pressure losses are generally divided into distributed e localized:

  • the former develop along the pipes,
  • the latter are associated with specific elements that change the flow conditions.

Part of the total resistance also comes from components that interrupt the uniform geometry of the piping: elbows, valves, fittings, filters, diameter reductions and measuring instruments change the direction, velocity or distribution of the flow, generating localized head losses.

A partially closed valve, for example, can introduce a much higher resistance than the same valve fully open. A series of elbows or fittings concentrated in one section of the line can therefore contribute significantly to the total resistance.

Filters also deserve particular attention: their pressure drop can increase progressively as material accumulates, so the hydraulic conditions of the system change between a clean filter and one close to its maintenance threshold.

The same applies to heat exchangers, treatment equipment and instruments installed along the line. When sizing a centrifugal pump, it is therefore important to consider the actual path of the liquid, rather than measuring only the length and diameter of the piping.

What happens if pressure losses are evaluated incorrectly

Underestimating or incompletely assessing the resistance of the circuit can cause the pump to operate under conditions different from those considered at the design stage. The effects depend on the system configuration and the characteristics of the machine, but they can affect both performance and long-term reliability.

Consequences to consider include:

  • Insufficient flow rate: if the head required by the plant is higher than expected, the duty point may shift toward a lower flow rate, compromising the transfer of the required amount of fluid;
  • Unstable operation: a flow rate different from the expected one can disrupt feeding, recirculation, heat exchange or other stages linked to product handling;
  • Unexpected power consumption: the shift of the duty point also changes the absorbed power and efficiency;
  • Noise and vibration: operating in unfavorable areas of the curve can be associated with internal recirculation, hydraulic instability and increased vibration;
  • Premature wear: inadequate operating conditions can increase the stress on the impeller, bearings and, in pumps that use them, mechanical seals, reducing long-term reliability.

To these phenomena is added cavitation, which calls for a specific assessment, especially on the suction side.

Pressure losses, available NPSH and cavitation

Head losses also help determine the available NPSH, or NPSHa. In practical terms, the greater the pressure loss along the suction line, the smaller the margin available at the pump inlet relative to the vapor pressure of the liquid.

The NPSHa of the system must be compared with the NPSH required by the pump, referred to as NPSHr, maintaining a margin appropriate to the operating conditions and to the guidelines applicable to the specific installation: a long suction line, an insufficient diameter, numerous elbows, or valves or filters that introduce resistance can reduce the available NPSH; liquid temperature, pressure in the suction tank and product properties also play a part in the assessment.

When the local pressure drops to the vapor pressure of the liquid, vapor bubbles can form and then collapse in areas of higher pressure. This is the phenomenon of cavitation, which can cause impeller erosion, noise, vibration, reduced performance and progressive damage to the pump.

Prolonged operation under these conditions can significantly shorten the service life of components. For this reason, checking the suction side must go hand in hand with calculating the head and selecting the pump.

Liquid viscosity: how it changes losses and performance

In chemical plants, viscosity can take very different values depending on the product handled and the operating temperature. As viscosity increases, the resistance to flow of the liquid grows, so head losses in the piping can increase.

The effect also concerns the centrifugal pump, since performance curves are generally determined using water under defined conditions; when the liquid has a significantly higher viscosity, actual performance may differ from that shown by the water curve.

Flow rate, head, efficiency and absorbed power must therefore be evaluated taking into account the real characteristics of the product: in particular, an increase in viscosity tends to reduce pump efficiency and may require specific correction factors to be applied.

Depending on the duty, impeller geometries and pump configurations better suited to the properties of the liquid can also be considered. Viscosity therefore affects both the behavior of the circuit and that of the machine, which is why it is such an important parameter when considering the possible head losses of the system.

Temperature and viscosity are also often correlated: when the operating temperature changes, the viscosity of the product can change too, altering the hydraulic conditions compared with those used for the initial sizing.

Assessing the entire circuit to choose the centrifugal pump

Required flow rate, elevation difference, head losses, viscosity, temperature, piping configuration and suction conditions all contribute to defining the actual duty point of a centrifugal pump.

Selection should therefore start from reliable data on the conditions expected during operation, also considering possible variations over time. A filter that gets dirty, a valve that changes position or a change in viscosity can alter the system curve and shift pump operation away from the initial condition.

In systems intended for handling aggressive and corrosive substances, the chemical compatibility of materials also comes into play, together with the construction of the machine and safety and maintenance requirements.

CDR Pompe supports companies and operators in choosing centrifugal pumps for chemical applications, offering magnetic drive and mechanical seal pumps, solutions in metallic and thermoplastic materials, and technical support in selecting the configuration best suited to the characteristics of the fluid and the system. A correct assessment of the operating conditions makes it possible to identify the pump most consistent with the required performance and to manage its operation over time with greater reliability.

Contact us for a consultation and to learn about all our services dedicated to the process industry.

Frequently Asked Questions

Do pressure losses stay constant while the plant is operating?

No. They can vary when the flow rate, viscosity, fluid temperature or circuit configuration change. Progressive phenomena such as scaling in the pipes and clogged filters can also increase hydraulic resistance. For this reason, when selecting the pump it is useful to evaluate several operating conditions rather than a single theoretical point, especially in plants subject to significant variations during operation.

Does a larger pipe diameter always reduce pressure losses?

At the same flow rate, increasing the internal diameter generally reduces the fluid velocity and therefore the distributed losses. However, pipe sizing must consider the entire plant, space constraints, product characteristics, costs and permissible flow velocities. Choosing very large diameters with the sole aim of minimizing losses is therefore not automatically the most suitable configuration.

How does scaling inside the piping affect pump performance?

Deposits and scaling can reduce the usable cross-section of the pipe and change its internal roughness. Both phenomena can increase pressure losses compared with the conditions considered during the initial sizing. A plant that shows a reduced flow rate after years of service does not necessarily have a pump problem: before working on the machine, it is advisable to check the condition of the circuit as well.

Can the fluid temperature change the pressure losses?

Yes. Temperature can change physical properties such as viscosity and density and, as a result, the behavior of the fluid in the pipes. In chemical plants this can be particularly relevant when the product is handled at very different temperatures. Temperature also comes into play in the NPSH check because it changes the vapor pressure of the liquid, with possible consequences for the available margin against cavitation.