XTN-BL – magnetically driven with an open impeller
The Series X it is suitable for applications with corrosive, toxic, or hazardous liquids when:
• The liquids being pumped have a high concentration of solids, therefore the use of a standard magnetic drive pump would cause frequent blockages and failures;
• a pump that complies with normative ATEX (ATEX Zone 1 indoor and outdoor).
The circulation of the fluid laden with solid particles is ensured by the large flushing channels within the pump. This way, the diamond bushings and the cup are properly cooled. The axial flushing hole in the impeller shaft also ensures a continuous exchange of pumped liquid between the cup and the volute.
Maximum allowable temperature up to +160°.
Main technical features of the model:
| Sealing System | Magnetic Drag |
| Design: | EN 22858; ISO 2858; ISO 15783 |
| Body Material: | PFA Lined |
| Bushings/Shaft Material: | Diamond Compound |
| Body Type: | Radially Split Volute Casing |
| Spinning Material | PFA Lined |
| Rotor Type: | Open |
| Aspiration Position | End suction |
| Pull-out design | Yes |
| Heating Shirt | North America |
| Connection Types: | Flanged |
| Flange | UNI 1092-2 (ISO 7005-2) PN16RF slotted to ANSI 150 |
| Self-priming | Non-priming |
| Lubricant | North America |
| Maximum Pressure Range @20°C: | Pressure Nominal 16 |
| Fluid Temperature Range: | PFA: -50°C / +160°C |
| Maximum prevalence @ 2900 RPM: | 60 meters |
| Maximum Flow @ 2900 RPM: | 70 m³/h |
| Viscosity Range | 0.5 cSt – 180 cSt |
| Maximum Installable Power | 18.5 kW |
Sign up for our newsletter
Get an exclusive look at the latest products and the most important news.
"*" indicates required fields