UCL - lined and plastic mechanical seal
Single-stage, sealless, plastic-lined, and fluoropolymer-lined centrifugal process pumps. Available materials: Polypropylene, PVDF (Polyvinylidene fluoride), PFA (perfluoroalkoxy). Execution on base (UCL) monoblock (UCL-B).
Versatility: Suitable for pumping corrosive, aggressive, and hazardous liquids (slightly contaminated, clean, low viscosity) for the chemical, petrochemical, and pharmaceutical industries.
Reliability: On pumps UCL It is possible to install different types of mechanical seals. A redesigned bearing support ensures a longer service life even in critical operating conditions.
Design: Pumps UCL They have the same hydraulics as the magnetic drive series UTN, process pumps for the chemical industry.



Main technical features of the model:
| Sealing System | Mechanical Grip |
| Design: | EN 22858; ISO 2858; ISO 5199 |
| Body Material: | PFA Lined – PVDF Lined – PP Lined |
| Body Type: | Radially Split Volute Casing |
| Spinning Material | PFA Lined – PVDF Lined – PP Lined |
| Rotor Type: | Closed, Radial |
| Intake Position: | End suction |
| Execution | Horizontal – Long-Coupled |
| Pull-out design | Yes |
| Heating Shirt | North America |
| Connection Types: | Flange |
| Flange | UNI 1092-2 (ISO 7005-2) PN16RF slotted to ANSI 150 |
| Self-priming | Non-priming |
| Lubrication: | Oil |
| Maximum Pressure Range @20°C: | Pressure Nominal 16 |
| Fluid Temperature Range: | PP: -10°C / +70°C PVDF: -30°C / +100°C PFA: -50°C / +140°C |
| Maximum Torque @ 2900 RPM: | 75 meters |
| Maximum Flow Rate @2900 RPM: | 250 meters3/h |
| Viscosity Range | 0.5 cSt – 180 cSt |
| Maximum Installable Power | 55 kW |
| Sealing System | Mechanical Grip |
| Design: | EN 22858; ISO 2858; ISO 5199 |
| Body Material: | PFA Lined – PVDF Lined – PP Lined |
| Body Type: | Radially Split Volute Casing |
| Spinning Material | PFA Lined – PVDF Lined – PP Lined |
| Rotor Type: | Closed, Radial |
| Intake Position: | End suction |
| Execution | Horizontal – Close-Coupled |
| Pull-out design | Yes |
| Heating Shirt | North America |
| Connection Types: | Flange |
| Flange | UNI 1092-2 (ISO 7005-2) PN16RF slotted to ANSI 150 |
| Self-priming | Non-priming |
| Lubrication: | North America |
| Maximum Pressure Range @20°C: | Pressure Nominal 16 |
| Fluid Temperature Range: | PP: -10°C / +70°C PVDF: -30°C / +100°C PFA: -50°C / +140°C |
| Maximum Torque @ 2900 RPM: | 75 meters |
| Maximum Flow Rate @2900 RPM: | 120 m3/h |
| Viscosity Range | 0.5 cSt – 180 cSt |
| Maximum Installable Power | 18.5 kW |
Sign up for our newsletter
Get an exclusive look at the latest products and the most important news.
"*" indicates required fields