{"id":7799,"date":"2026-05-27T09:22:13","date_gmt":"2026-05-27T07:22:13","guid":{"rendered":"https:\/\/www.cdrpompe.com\/?p=7799"},"modified":"2026-06-24T11:20:43","modified_gmt":"2026-06-24T09:20:43","slug":"steel-pumps-vs-lined-pumps-guide-to-selection-in-processes-with-aggressive-fluids","status":"publish","type":"post","link":"https:\/\/www.cdrpompe.com\/en\/steel-pumps-vs-lined-pumps-guide-to-selection-in-processes-with-aggressive-fluids\/","title":{"rendered":"Steel Pumps vs Lined Pumps: guide to selection in processes with aggressive fluids"},"content":{"rendered":"<h2><b>Summary<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">The choice between steel pumps and lined pumps is a key step in the design and management of industrial systems where fluids with different chemical characteristics are handled. The decision affects not only system efficiency but also the safety of operators, equipment, and the environment, especially when working with potentially corrosive substances.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Steel pumps offer advantages such as mechanical strength, the ability to operate at high temperatures, and reliability with non-aggressive fluids such as water, oils, and non-reactive solvents. However, their limitations emerge in contact with strong acids or highly corrosive solutions.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Lined pumps, on the other hand, use materials such as PP, PVDF, ETFE, and PFA to provide effective protection against chemical attack by isolating metal surfaces and reducing corrosion phenomena.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The article guides the reader in selecting the <a href=\"https:\/\/www.cdrpompe.com\/en\/\" target=\"_blank\" rel=\"noopener\">most suitable solution based on fluid type<\/a>, operating conditions, and chemical aggressiveness.<\/span><\/p>\n<h2><b>Steel and Lined Pumps: How to Choose<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Plant safety is the first factor to consider when installing a new component. Poor technical choices can expose workers, equipment, and the environment to significant risks, especially when handling corrosive or aggressive fluids.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Choosing between <\/span><b>steel pumps and <a href=\"https:\/\/www.cdrpompe.com\/en\/lined-pumps-car\/\" target=\"_blank\" rel=\"noopener\">lined pumps<\/a><\/b><span style=\"font-weight: 400;\"> is crucial, since the pump body is directly exposed to the fluid. Any incompatibility can lead to corrosion, structural weakening, and leaks.<\/span><\/p>\n<h2><b>Steel Pumps (AISI 304): Features and Applications<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Pumps made of <\/span><b>AISI 304 stainless steel<\/b><span style=\"font-weight: 400;\"> offer:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Mechanical strength<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Structural stability<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Versatility<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">They provide good corrosion resistance when handling non-aggressive fluids and are widely used in:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">water treatment<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">manufacturing processes<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">light chemical applications<\/span><\/li>\n<\/ul>\n<h3><b>Limits of Steel Pumps with Aggressive Fluids<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">With strong acids such as:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">hydrochloric acid (HCl)<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">sulfuric acid (H\u2082SO\u2084)<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">steel becomes vulnerable to corrosion, leading to:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">surface degradation<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">micro-cavities<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">potential leaks<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Material compatibility must always be evaluated carefully during the selection phase.<\/span><\/p>\n<h2><b>Performance of Steel Pumps<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Steel pumps are particularly appreciated for:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Operating temperature range: approx. -40\u00b0C to +300\u00b0C<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">High pressure resistance<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Ability to handle mechanical stress<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">They are ideal in demanding industrial environments with dynamic loads and vibrations.<\/span><\/p>\n<h2><b>Lined Pumps: Structure and Materials<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Lined pumps consist of:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">a metal external structure (mechanical strength)<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">an internal lining (chemical protection)<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Common lining materials:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">PP<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">PVDF<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">ETFE<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">PFA<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">This construction prevents the fluid from coming into contact with metal surfaces.<\/span><\/p>\n<h3><b>Advantages of Lined Pumps<\/b><\/h3>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>High chemical resistance<\/b><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Separation between fluid and metal<\/b><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Reduced contamination risk<\/b><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Stable internal surfaces<\/b><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Cost-effective alternative to special alloys<\/b><\/li>\n<\/ul>\n<h3><b>When to Choose Steel Pumps<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Steel pumps are suitable when:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Fluids are non-aggressive<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">High temperatures are required<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">High pressure conditions are present<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Mechanical stress and vibrations are significant<\/span><\/li>\n<\/ul>\n<h3><b>When to Choose Lined Pumps<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Lined pumps are preferred when:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Strong acids or bases are involved<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Aggressive industrial effluents are handled<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Chemical compatibility is the priority<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Leakage risks must be minimized<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Operating conditions are chemically critical<\/span><\/li>\n<\/ul>\n<h3><b>Key Selection Factors<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">The choice between steel and lined pumps depends on balancing:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Mechanical resistance<\/b><span style=\"font-weight: 400;\"> (steel)<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Chemical resistance<\/b><span style=\"font-weight: 400;\"> (lined pumps)<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Correct material selection ensures safety, reliability, and <a href=\"https:\/\/www.cdrpompe.com\/en\/contact\/\" target=\"_blank\" rel=\"noopener\">long-term efficiency.<\/a><\/span><\/p>\n<h3><b>FAQ<\/b><\/h3>\n<h4><b>Can lined pumps operate at high temperatures?<\/b><\/h4>\n<p><span style=\"font-weight: 400;\">Yes, but within lower limits than steel pumps, depending on the lining material.<\/span><\/p>\n<h4><b>When should steel pumps be avoided?<\/b><\/h4>\n<p><span style=\"font-weight: 400;\">When handling highly corrosive fluids such as concentrated acids or aggressive saline solutions.<\/span><\/p>\n<h4><b>What is the main difference?<\/b><\/h4>\n<p><span style=\"font-weight: 400;\">Steel pumps expose metal directly to the fluid, while lined pumps use a protective inner layer to isolate the metal.<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Summary The choice between steel pumps and lined pumps is a key step in the design and management of industrial&#8230;<\/p>\n","protected":false},"author":4,"featured_media":7741,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[41],"tags":[],"class_list":["post-7799","post","type-post","status-publish","format-standard","has-post-thumbnail","category-news-en"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Steel and Lined Pumps: Balancing Safety and Fluid Handling<\/title>\n<meta name=\"description\" content=\"Find out when to use stainless steel pumps or lined pumps: a technical guide to choosing based on fluids, safety, and chemical compatibility\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.cdrpompe.com\/en\/steel-pumps-vs-lined-pumps-guide-to-selection-in-processes-with-aggressive-fluids\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Steel and Lined Pumps: Balancing Safety and Fluid Handling\" \/>\n<meta property=\"og:description\" content=\"Find out when to use stainless steel pumps or lined pumps: a technical guide to choosing based on fluids, safety, and chemical compatibility\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.cdrpompe.com\/en\/steel-pumps-vs-lined-pumps-guide-to-selection-in-processes-with-aggressive-fluids\/\" \/>\n<meta property=\"og:site_name\" content=\"CDR Pompe\" \/>\n<meta property=\"article:published_time\" content=\"2026-05-27T07:22:13+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-24T09:20:43+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.cdrpompe.com\/wp-content\/uploads\/2026\/05\/pompa-cdr-pompa-volumetrica-1-thegem-blog-default.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1170\" \/>\n\t<meta property=\"og:image:height\" content=\"540\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"cdr-SEO\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"cdr-SEO\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.cdrpompe.com\\\/en\\\/steel-pumps-vs-lined-pumps-guide-to-selection-in-processes-with-aggressive-fluids\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.cdrpompe.com\\\/en\\\/steel-pumps-vs-lined-pumps-guide-to-selection-in-processes-with-aggressive-fluids\\\/\"},\"author\":{\"name\":\"cdr-SEO\",\"@id\":\"https:\\\/\\\/www.cdrpompe.com\\\/en\\\/#\\\/schema\\\/person\\\/e8db68b3084c8f9b1cb9bda497aceb2b\"},\"headline\":\"Steel Pumps vs Lined Pumps: guide to selection in processes with aggressive fluids\",\"datePublished\":\"2026-05-27T07:22:13+00:00\",\"dateModified\":\"2026-06-24T09:20:43+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.cdrpompe.com\\\/en\\\/steel-pumps-vs-lined-pumps-guide-to-selection-in-processes-with-aggressive-fluids\\\/\"},\"wordCount\":564,\"image\":{\"@id\":\"https:\\\/\\\/www.cdrpompe.com\\\/en\\\/steel-pumps-vs-lined-pumps-guide-to-selection-in-processes-with-aggressive-fluids\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.cdrpompe.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/pompa-cdr-pompa-volumetrica-1-thegem-blog-default.webp\",\"articleSection\":[\"News\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.cdrpompe.com\\\/en\\\/steel-pumps-vs-lined-pumps-guide-to-selection-in-processes-with-aggressive-fluids\\\/\",\"url\":\"https:\\\/\\\/www.cdrpompe.com\\\/en\\\/steel-pumps-vs-lined-pumps-guide-to-selection-in-processes-with-aggressive-fluids\\\/\",\"name\":\"Steel and Lined Pumps: Balancing Safety and Fluid Handling\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.cdrpompe.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.cdrpompe.com\\\/en\\\/steel-pumps-vs-lined-pumps-guide-to-selection-in-processes-with-aggressive-fluids\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.cdrpompe.com\\\/en\\\/steel-pumps-vs-lined-pumps-guide-to-selection-in-processes-with-aggressive-fluids\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.cdrpompe.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/pompa-cdr-pompa-volumetrica-1-thegem-blog-default.webp\",\"datePublished\":\"2026-05-27T07:22:13+00:00\",\"dateModified\":\"2026-06-24T09:20:43+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.cdrpompe.com\\\/en\\\/#\\\/schema\\\/person\\\/e8db68b3084c8f9b1cb9bda497aceb2b\"},\"description\":\"Find out when to use stainless steel pumps or lined pumps: a technical guide to choosing based on fluids, safety, and chemical compatibility\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.cdrpompe.com\\\/en\\\/steel-pumps-vs-lined-pumps-guide-to-selection-in-processes-with-aggressive-fluids\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.cdrpompe.com\\\/en\\\/steel-pumps-vs-lined-pumps-guide-to-selection-in-processes-with-aggressive-fluids\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.cdrpompe.com\\\/en\\\/steel-pumps-vs-lined-pumps-guide-to-selection-in-processes-with-aggressive-fluids\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.cdrpompe.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/pompa-cdr-pompa-volumetrica-1-thegem-blog-default.webp\",\"contentUrl\":\"https:\\\/\\\/www.cdrpompe.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/pompa-cdr-pompa-volumetrica-1-thegem-blog-default.webp\",\"width\":1170,\"height\":540},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.cdrpompe.com\\\/en\\\/steel-pumps-vs-lined-pumps-guide-to-selection-in-processes-with-aggressive-fluids\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.cdrpompe.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Steel Pumps vs Lined Pumps: guide to selection in processes with aggressive fluids\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.cdrpompe.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.cdrpompe.com\\\/en\\\/\",\"name\":\"CDR Pompe\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.cdrpompe.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.cdrpompe.com\\\/en\\\/#\\\/schema\\\/person\\\/e8db68b3084c8f9b1cb9bda497aceb2b\",\"name\":\"cdr-SEO\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c87423d6f8dac8c516d044ddcd1ce89667e0701144c662a55336eae4dd7fcf96?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c87423d6f8dac8c516d044ddcd1ce89667e0701144c662a55336eae4dd7fcf96?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c87423d6f8dac8c516d044ddcd1ce89667e0701144c662a55336eae4dd7fcf96?s=96&d=mm&r=g\",\"caption\":\"cdr-SEO\"},\"url\":\"https:\\\/\\\/www.cdrpompe.com\\\/en\\\/author\\\/cdr-seo\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Steel and Lined Pumps: Balancing Safety and Fluid Handling","description":"Find out when to use stainless steel pumps or lined pumps: a technical guide to choosing based on fluids, safety, and chemical compatibility","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.cdrpompe.com\/en\/steel-pumps-vs-lined-pumps-guide-to-selection-in-processes-with-aggressive-fluids\/","og_locale":"en_US","og_type":"article","og_title":"Steel and Lined Pumps: Balancing Safety and Fluid Handling","og_description":"Find out when to use stainless steel pumps or lined pumps: a technical guide to choosing based on fluids, safety, and chemical compatibility","og_url":"https:\/\/www.cdrpompe.com\/en\/steel-pumps-vs-lined-pumps-guide-to-selection-in-processes-with-aggressive-fluids\/","og_site_name":"CDR Pompe","article_published_time":"2026-05-27T07:22:13+00:00","article_modified_time":"2026-06-24T09:20:43+00:00","og_image":[{"width":1170,"height":540,"url":"https:\/\/www.cdrpompe.com\/wp-content\/uploads\/2026\/05\/pompa-cdr-pompa-volumetrica-1-thegem-blog-default.webp","type":"image\/webp"}],"author":"cdr-SEO","twitter_card":"summary_large_image","twitter_misc":{"Written by":"cdr-SEO","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.cdrpompe.com\/en\/steel-pumps-vs-lined-pumps-guide-to-selection-in-processes-with-aggressive-fluids\/#article","isPartOf":{"@id":"https:\/\/www.cdrpompe.com\/en\/steel-pumps-vs-lined-pumps-guide-to-selection-in-processes-with-aggressive-fluids\/"},"author":{"name":"cdr-SEO","@id":"https:\/\/www.cdrpompe.com\/en\/#\/schema\/person\/e8db68b3084c8f9b1cb9bda497aceb2b"},"headline":"Steel Pumps vs Lined Pumps: guide to selection in processes with aggressive fluids","datePublished":"2026-05-27T07:22:13+00:00","dateModified":"2026-06-24T09:20:43+00:00","mainEntityOfPage":{"@id":"https:\/\/www.cdrpompe.com\/en\/steel-pumps-vs-lined-pumps-guide-to-selection-in-processes-with-aggressive-fluids\/"},"wordCount":564,"image":{"@id":"https:\/\/www.cdrpompe.com\/en\/steel-pumps-vs-lined-pumps-guide-to-selection-in-processes-with-aggressive-fluids\/#primaryimage"},"thumbnailUrl":"https:\/\/www.cdrpompe.com\/wp-content\/uploads\/2026\/05\/pompa-cdr-pompa-volumetrica-1-thegem-blog-default.webp","articleSection":["News"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.cdrpompe.com\/en\/steel-pumps-vs-lined-pumps-guide-to-selection-in-processes-with-aggressive-fluids\/","url":"https:\/\/www.cdrpompe.com\/en\/steel-pumps-vs-lined-pumps-guide-to-selection-in-processes-with-aggressive-fluids\/","name":"Steel and Lined Pumps: Balancing Safety and Fluid Handling","isPartOf":{"@id":"https:\/\/www.cdrpompe.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.cdrpompe.com\/en\/steel-pumps-vs-lined-pumps-guide-to-selection-in-processes-with-aggressive-fluids\/#primaryimage"},"image":{"@id":"https:\/\/www.cdrpompe.com\/en\/steel-pumps-vs-lined-pumps-guide-to-selection-in-processes-with-aggressive-fluids\/#primaryimage"},"thumbnailUrl":"https:\/\/www.cdrpompe.com\/wp-content\/uploads\/2026\/05\/pompa-cdr-pompa-volumetrica-1-thegem-blog-default.webp","datePublished":"2026-05-27T07:22:13+00:00","dateModified":"2026-06-24T09:20:43+00:00","author":{"@id":"https:\/\/www.cdrpompe.com\/en\/#\/schema\/person\/e8db68b3084c8f9b1cb9bda497aceb2b"},"description":"Find out when to use stainless steel pumps or lined pumps: a technical guide to choosing based on fluids, safety, and chemical compatibility","breadcrumb":{"@id":"https:\/\/www.cdrpompe.com\/en\/steel-pumps-vs-lined-pumps-guide-to-selection-in-processes-with-aggressive-fluids\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.cdrpompe.com\/en\/steel-pumps-vs-lined-pumps-guide-to-selection-in-processes-with-aggressive-fluids\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.cdrpompe.com\/en\/steel-pumps-vs-lined-pumps-guide-to-selection-in-processes-with-aggressive-fluids\/#primaryimage","url":"https:\/\/www.cdrpompe.com\/wp-content\/uploads\/2026\/05\/pompa-cdr-pompa-volumetrica-1-thegem-blog-default.webp","contentUrl":"https:\/\/www.cdrpompe.com\/wp-content\/uploads\/2026\/05\/pompa-cdr-pompa-volumetrica-1-thegem-blog-default.webp","width":1170,"height":540},{"@type":"BreadcrumbList","@id":"https:\/\/www.cdrpompe.com\/en\/steel-pumps-vs-lined-pumps-guide-to-selection-in-processes-with-aggressive-fluids\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.cdrpompe.com\/en\/"},{"@type":"ListItem","position":2,"name":"Steel Pumps vs Lined Pumps: guide to selection in processes with aggressive fluids"}]},{"@type":"WebSite","@id":"https:\/\/www.cdrpompe.com\/en\/#website","url":"https:\/\/www.cdrpompe.com\/en\/","name":"CDR Pompe","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.cdrpompe.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.cdrpompe.com\/en\/#\/schema\/person\/e8db68b3084c8f9b1cb9bda497aceb2b","name":"cdr-SEO","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/c87423d6f8dac8c516d044ddcd1ce89667e0701144c662a55336eae4dd7fcf96?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/c87423d6f8dac8c516d044ddcd1ce89667e0701144c662a55336eae4dd7fcf96?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/c87423d6f8dac8c516d044ddcd1ce89667e0701144c662a55336eae4dd7fcf96?s=96&d=mm&r=g","caption":"cdr-SEO"},"url":"https:\/\/www.cdrpompe.com\/en\/author\/cdr-seo\/"}]}},"atf_populated":false,"menu_order":0,"_links":{"self":[{"href":"https:\/\/www.cdrpompe.com\/en\/wp-json\/wp\/v2\/posts\/7799","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.cdrpompe.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.cdrpompe.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.cdrpompe.com\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.cdrpompe.com\/en\/wp-json\/wp\/v2\/comments?post=7799"}],"version-history":[{"count":1,"href":"https:\/\/www.cdrpompe.com\/en\/wp-json\/wp\/v2\/posts\/7799\/revisions"}],"predecessor-version":[{"id":7800,"href":"https:\/\/www.cdrpompe.com\/en\/wp-json\/wp\/v2\/posts\/7799\/revisions\/7800"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.cdrpompe.com\/en\/wp-json\/wp\/v2\/media\/7741"}],"wp:attachment":[{"href":"https:\/\/www.cdrpompe.com\/en\/wp-json\/wp\/v2\/media?parent=7799"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.cdrpompe.com\/en\/wp-json\/wp\/v2\/categories?post=7799"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.cdrpompe.com\/en\/wp-json\/wp\/v2\/tags?post=7799"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}